Sector | Engineering firm, head office |
Scope | Head office, 220 hosts |
Findings | Critical 0 · High 2 · Low 5 |
Result | Sessions revoked, hardware keys issued |
Written for the client's board. Names, sites and hostnames are removed from this copy.
An engineer at a firm in city withheld saw drawings open on the file share from a device she did not own. Her password had not changed and her second factor had not been touched.
The token was taken after sign-in, through a lookalike page. We revoked every session for the account first, then reset the password, because a reset alone would have left the token alive.
We rebuilt what the session read from the file share logs and gave the client an exact list. Hardware keys went out to the staff with access to client drawings.
Copied from the case record. Times are local to the head office.
Time | Event | By | Elapsed |
13:10 | Client calls the 24/7 line | Client | 0 min |
13:22 | Lead named, scope agreed | Lead | 12 min |
14:05 | Sign-in logs show a token in use on a new device | Analyst | 55 min |
15:18 | Lookalike sign-in page found in mail logs | Analyst | 2 h 08 min |
15:40 | Client approves revoking sessions | Client | 2 h 30 min |
15:46 | Sessions revoked, then password reset | Lead | 2 h 36 min |
17:12 | File share logs copied and logged | Forensics | 4 h 02 min |
18:40 | Contained. No live sessions, list of files agreed. | Lead | 5 h 30 min |
After containment | |||
Day 2 | List of files read given to the client | Analyst | Closed |
Day 7 | Report delivered, lead signs the last page | Lead | Closed |
Day 15 | Hardware keys issued to drawing staff | Client IT | Closed |
Day 30 | Closing review with leadership | Lead | Closed |
Severity | Finding | Status |
High | Sessions last 30 days on file share accounts | Day 6 |
High | Sign-in codes open to a lookalike page | Day 15 |
Low | finding withheld | Closed |
Low | finding withheld | Closed |

Critical | 0 |
High | 2 |
Low | 5 |
We had done what everyone tells you to do. They showed us exactly where that stopped, and what came next.
Hardware keys for staff with client drawings
Sessions end after 12 hours
Revoke first, then reset: now in the runbook