“Under 20 milliseconds” is the number on every Vesper brochure. Here is what actually happens inside that blink.
0 ms — the grid wobbles
The gateway beside your meter watches the grid voltage and frequency thousands of times a second. When either falls outside safe limits, it decides the grid has failed.
2–10 ms — the house is islanded
A relay opens and disconnects your home from the street. This matters: it stops your battery feeding power back into lines that utility crews may be working on.
10–20 ms — the battery takes the load
The inverter, already synchronised with the grid, keeps the same waveform going from the battery. To your lights and router it looks like nothing happened.
Afterwards
The app pings you. The battery runs the essentials circuit, holds back nothing for the grid and keeps going until the street is stable again. Then the gateway waits a few minutes, checks the grid is steady and reconnects on its own.
Most owners only know any of this happened because the street lights went out.