Bifacial modules collect light on both faces. On a bright white TPO roof, the rear side picks up reflected light that a standard module wastes. Datasheets promise anything from 5 to 20% more energy. We wanted our own number.
The test
On one distribution centre roof we installed two identical 100 kWp blocks side by side, same tilt, same inverter model, same cleaning schedule. One block used bifacial modules, the other standard monofacial modules of the same rating.
The result
Over twelve months the bifacial block produced 7.8% more energy. The gain was highest in summer, when the roof surface was cleanest and brightest, and fell to about 4% in winter, when dust and a lower sun reduced reflection.
What it means for a project
- Specify bifacial on new white membranes and on high-mount carports
- Raise the modules: every extra 10 cm of clearance added around one point of gain
- Keep the roof clean — the gain halves on a dirty membrane
- Do not pay a premium above the measured gain for your site
We now model bifacial gain with our own measured coefficients, not the datasheet figure.