FLEET STATUS · 338 / 340 sites online · uptime 99.6% (2025)
Mon–Fri 7:00–18:00 CT     Careers     Client Portal
SALES DESK
+1-555-0188
HEAD OFFICE
1180 Meridian Pkwy, Ashford TX
FEASIBILITY
10-day desk study, no fee
Home / Solutions / Solar Carports
DOC NB-P03 · REV. 10/2026
[ Solution S-02 ]

Solar carports,
parking that makes power.

Galvanised steel canopies from 40 to 900 bays that shade staff and fleet parking, feed EV chargers below and drain to your storm system — single or double cantilever, engineered for 140 mph wind.

40 – 900 BAYS
8–14 WKS ON SITE
140 MPH WIND RATED
SOLUTION FILE
S-02 · CARPORT
6–8YEARS
Typical simple payback for an owner-funded carport.
CANOPIES BUILT
118
SHARE OF FLEET
17% · 70 MWp
CHARGING
Level 2 + DC fast
 
ON THIS PAGE
01   Scope
02   Standard spec
03   Canopy types
04   Projects & FAQ
01 / Scope

One contract from car-park survey to year 25.

A carport is the most structurally demanding system we build: every column carries the whole canopy against wind and drifting snow. So we start underground — services, soil and drainage — and fix the layout before a single module is chosen.

Charger conduit goes in while the foundations are open, even if the chargers come later. Trenching once costs a fraction of trenching twice, and the team that pours the piles stays on the O&M contract.

CANOPIES
118
EV-READY
72%
WIND CLAIMS
0
Solar canopy with EV charging cabinets over a car park
DETAIL C-02 · CANTILEVER FRAME
3.0–4.2 m clear · 140 mph
FIG. 01 — Single-cantilever frame with the charger cabinets on the column line
IN SCOPE · STANDARD CONTRACT
10 ITEMS
Underground services & soil survey
Structural design for wind & snow
Layout around lanes, lighting & access
Building, zoning & utility permits
Piles, steel, modules, inverters
Gutters piped to your storm system
Charger conduit laid with the foundations
LED lighting under every bay
Commissioning & witness testing
O&M contract up to 25 years
OPTIONAL · OR BY OTHERS
EV chargers, Level 2 or DC fast
SUPPLIED & INSTALLED ON REQUEST
Battery buffer for fast chargers
SEE S-04 · STORAGE
Resurfacing & line marking
WE COORDINATE YOUR CONTRACTOR
Rooftop array on the same meter
SEE S-01 · ROOFTOP
02 / Standard spec

The spec sheet every canopy starts from.

We only deviate when your site gives us a reason — soil, snow, delivery heights — and every deviation is written into the proposal so your engineers can challenge it.

SPEC SHEET · S-02 STANDARD
REV. C
ITEM
STANDARD
OPTION
STRUCTURE
Galvanised steel, single cantilever
Double cantilever over two rows
FOUNDATIONS
Bored piles, sized to the soil report
Spread footings on rock
CLEARANCE
3.0 m at the low edge
4.2 m where delivery vans park
MODULES
Tier-1 bifacial, 430–450 W
Glass-glass for a dry underside
WIND & SNOW
140 mph, local snow load
Drift design at the low edge
DRAINAGE
Gutters piped to your storm system
Rainwater tank connection
EV CHARGING
Conduit to every second column
Level 2 or DC fast, installed
WARRANTIES
25-yr module · 25-yr steel · 10-yr workmanship
Extended inverter cover to 20 yrs
YIELD GUARANTEE
95% of P90, settled in cash yearly
—
Fleet vans parked at a row of EV chargers
YIELD GUARANTEE
Miss 95% of the P90 yield and we pay the difference — canopies included.
101.2%
Ashford Civic, year one
25yrs
Guarantee term
03 / Canopy types

Four canopy layouts cover almost every car park.

Each has its own column grid, steel weight and clearance rule. If your car park is something else — a slope, a delivery yard, a heritage frontage — we have a detail for that too.

C-1

Single Cantilever

Columns at the kerb end of the bay: free lanes and easy parking, more steel per space.

COVERS
1 row of bays
COLUMNS
Kerb line, every 3 bays
STEEL / BAY
Higher
OUR CANOPIES
38%
C-2

Double Cantilever

One line of columns down the middle covers two rows — the least steel per space.

COVERS
2 rows of bays
COLUMNS
Centre line, every 3 bays
STEEL / BAY
Lowest
OUR CANOPIES
44%
C-3

Long-Span Fleet

Wide spans over van and truck bays, with 4.2 m clear for deliveries.

COVERS
Fleet & delivery bays
COLUMNS
Every 4–6 bays
STEEL / BAY
Highest
OUR CANOPIES
11%
C-4

Deck-Top Canopy

Low frames on the top level of a parking structure, bolted to the deck columns.

COVERS
Top deck
COLUMNS
On deck columns
STEEL / BAY
Low
OUR CANOPIES
7%
SITE CHECK
10 days, included in every carport study.
01
DAY 1–3
Services survey
Ground radar for cables, pipes and drains
02
DAY 4–6
Soil & drainage
Bore logs, infiltration and storm connections
03
DAY 7–9
Structure model
Wind, snow drift and vehicle impact at columns
04
DAY 10
Stamped letter
Licensed engineer signs before the layout goes out
04 / Carport projects

Three car parks, three spec sheets you can check.

Solar carport canopies over a staff car park with EV chargers

Ashford Civic Solar Canopy

Carport · 64 bays · 101.2% of P50
310 kWp
Northbeam head office building in Ashford

Caldwell Community College

Rooftop + carport · 101.8% of P50
740 kWp
Close-up of solar module rails and clamps on a membrane roof

Monoline Retail Park

Rooftop + carport · 100.7% of P50
880 kWp
05 / FAQ

Carport questions facilities teams ask first.

Short answers here; the long ones are in the feasibility report, with your car park’s numbers in them.

Portrait of Priya Nandakumar
Ask Priya’s team
Canopy & structural desk
PHONE
REPLY
Within one working day

Single or double cantilever — which do we need?

Double cantilever covers two rows of cars from one line of columns and uses the least steel per space. Single cantilever keeps the columns at the kerb, frees the driving lanes and is easier to park under, but costs more. The site survey usually decides it.

How tall are the canopies?

Our standard is 3.0 m clear at the low edge, which suits cars and most vans. Where delivery vans or trucks park we design for 4.2 m, and the clearance is marked on every column.

Will we lose parking during the build?

Very little. We build a row at a time and keep the rest open: piles first, then steel and modules in the same week. Even on our largest car parks, no more than about thirty bays have been closed at once.

Should we add EV chargers now or later?

Lay the conduit now even if the chargers come later — trenching while the foundations are open costs a fraction of trenching twice. We agree the charger power level before sizing the electrical room.

What happens to rain and snow?

Each canopy falls to a gutter piped into your storm system, so water never sheets onto cars or walkways. Snow loads and drifting at the low edge are designed in from your local code values.

Who maintains the canopy after handover?

The same team that designed and built it. Our O&M desk watches every string live, answers alarms 24 / 7 and checks steel, bolts and gutters on every scheduled visit — on contracts of up to 25 years.

Next step / Feasibility study

Send 12 months of bills. Get three priced options in 10 working days.

NO FEE · NO OBLIGATION · AN ENGINEER REPLIES IN ONE WORKING DAY
DIRECT LINES
SALES DESK
+1-555-0188
O&M DESK
24 / 7 / 365