FLEET STATUS · 338 / 340 sites online · uptime 99.6% (2025)
Mon–Fri 7:00–18:00 CT     Careers     Client Portal
SALES DESK
+1-555-0188
HEAD OFFICE
1180 Meridian Pkwy, Ashford TX
FEASIBILITY
10-day desk study, no fee
Home / Projects / Kestrel Packhouse
DOC NB-P13 · REV. 10/2026
[ Project NB-0377 · Agri & Food ]

Kestrel Foods
packs the harvest on solar.

A fruit packhouse near Waco whose cold rooms peak with the afternoon sun. The client owns a 640 kWp roof array and a 1 MWh battery beside the cold store, which carries the evening packing shift and cut peak demand from 910 kW to 610 kW.

AGRI & FOOD
WACO, TX
ENERGISED OCT 2024
PROJECT FILE
NB-0377 · REV. C
640kWp
Rooftop array plus a 1 MWh battery beside the cold store, owner-funded.
CLIENT
Kestrel Foods
MODEL
Owned · capex
YIELD VS P50
103.4%
 
ON THIS PAGE
01   Spec sheet
02   Demand profile
03   Timeline
04   Gallery
01 / Spec sheet

Sized for the packing shift, not for the brochure.

As-built figures plus the harvest-2025 meter and battery-controller data. The array is the worked example on our Financing page; the battery was priced on top of it.

Aerial view of a logistics warehouse with a rooftop solar array and loading docks
NB-0377
AS-BUILT · OCT 2024
FIG. 01 — 1,524 modules on the packhouse and cold-store roofs
DRONE SURVEY · NOV 2024
FIG. 01 — 1,524 modules on the packhouse and cold-store roofs
DRONE SURVEY · NOV 2024
SPEC SHEET · KESTREL FOODS
REV. C
SITE
Waco, TX · fruit packhouse
ROOF
Metal standing seam · R-1
CAPACITY (DC / AC)
640 kWp / 550 kW
MODULES
1,524 × 420 W mono
STORAGE
1 MWh / 500 kW LFP
ANNUAL YIELD
928 MWh P50 · 960 yr 1
DAYTIME LOAD FROM SOLAR
74%, harvest 2025
PEAK DEMAND
910 → 610 kW
CO₂ AVOIDED
374 t / year
ARRAY COST
$627,200 · $0.98 / Wp
COMMERCIAL MODEL
Owned (capex)
CHALLENGE
Harvest runs June to September, when afternoons pass 38 °C and the cold rooms work hardest. Blast chillers starting at 16:00 set a 910 kW peak just as the evening packing shift began.
ENGINEERING RESPONSE
A 640 kWp array on the packhouse roof for the daytime load, and a 1 MWh battery beside the cold store sized for the evening shift rather than for backup — the option that paid back best.
RESULT
Through harvest 2025 solar met 74% of daytime load, peak demand fell to 610 kW, yield ran at 103.4% of P50 and there was no unplanned downtime.
02 / Demand profile

The four o’clock peak, before and after.

The array carries the cold rooms through the middle of the day; the battery takes the blast chillers and the packing line from 16:00. Same harvest weekday, August 2024 versus August 2025.

GRID IMPORT · HARVEST WEEKDAY · kW
BEFORE
AFTER
 
250 kW
 
500 kW
 
750 kW
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
00:00
02:00
04:00
06:00
08:00
10:00
12:00
14:00
16:00
18:00
20:00
22:00
00
02
04
06
08
10
12
14
16
18
20
22
PEAK 910 → 610 kW
BATTERY 16:00–22:00
SOLAR 07:00–18:00
AUGUST BILL
2024 VS 2025
LINE
BEFORE
AFTER
Energy charges
$44,100
$28,500
Demand charges
$12,740
$8,540
Fixed & riders
$1,900
$1,900
Total
$58,740
$38,940
−33%
PEAK DEMAND
74%
DAYTIME LOAD FROM SOLAR
03 / Timeline

Eight months, built around one harvest.

The roof work ran through the 2024 harvest, so crews started at dawn and stayed clear of the loading yard once the trucks arrived.

FEB 2024
 
Feasibility study
Interval data from two harvests, a roof check and three priced options.
PHASE 01
APR 2024
 
Capex approved
Owner-funded, decided on the same model sheet shown on our Financing page.
PHASE 02
JUN 2024
 
Grid approval
Utility agreement at a 550 kW inverter limit, no service upgrade.
PHASE 03
AUG 2024
 
Mobilised
Dawn shifts on the roof; battery skid set on a new pad by the cold store.
PHASE 04
OCT 2024
 
Energised
Commissioned and witnessed by the utility, eight weeks after mobilisation.
LIVE
SEP 2025
 
First full harvest
Solar 74% of daytime load, peak 610 kW, no unplanned downtime.
O&M
8WEEKS
Mobilisation to energised
0LTI
Lost-time incidents
1DAY
Trailer-bay tie-in, via spare conduit
−300kW
Peak demand, harvest 2025
05 / Client voice
“Our worst hour used to be four o’clock in August. Now the battery takes it, the packing line never notices, and when we added a refrigerated trailer bay the conduit was already in the ground.”
LC
Luis Carranza
OPERATIONS DIRECTOR · KESTREL FOODS
HARVEST 2025 VS MODEL
SEP 2025
METRIC
MODEL
ACTUAL
Yield vs P50
100%
103.4%
Daytime solar share
70%
74%
Peak demand
650 kW
610 kW
Unplanned downtime
—
None
June–September 2025, weather-corrected revenue-meter and battery-controller data.
MORE FROM THE REGISTER
Ground-mounted solar rows beside a gravel service road
PREVIOUS · NB-0365

Teller Precision Plant

Manufacturing · 1.6 MWp
Solar carport canopies over a staff car park with EV chargers
NEXT · NB-0398

Ashford Civic Solar Canopy

Campuses · 310 kWp
Next step / Feasibility study

Send 12 months of bills. Get three priced options in 10 working days.

NO FEE · NO OBLIGATION · AN ENGINEER REPLIES IN ONE WORKING DAY
DIRECT LINES
SALES DESK
+1-555-0188
O&M DESK
24 / 7 / 365